When Starting Switch Is Turned To On Position (With Engine Stopped), Basic Check Monitor Lights Up - Komatsu PC200-8M0 Shop Manual

Table of Contents

Advertisement

SEN06138-00
E-4 When starting switch is turned to ON position (with engine stopped), basic check monitor lights
E-4 When starting switch is turned to ON position (with engine stopped),
basic check monitor lights up.
1) When starting switch is turned to ON position (with engine stopped), engine oil level monitor
Failure
lights up in yellow.
Related information
Cause
Defective engine oil level switch
1
system (machine monitor system)
Failure
2) Radiator coolant level monitor lights up in yellow.
Related information
Cause
Radiator sub tank coolant level
1
switch system
20
40-400
Procedure, measuring location, criteria and remarks
Perform troubleshooting for failure code [B@BAZK].
Procedure, measuring location, criteria and remarks
Perform troubleshooting for failure code [B@BCZK].
400 Troubleshooting of electrical system (E-mode)