Komatsu PC200-8M0 Shop Manual page 487

Table of Contents

Advertisement

103 Testing and adjusting, Part 3
Pm Clinic service
* Gauge changing work: Change hoses of gauges [3] and [4].
No.
Check item
Fuel
control
dial
8
Servo piston
MAX
Checked oil pressure
H (Servo control pressure)
* Gauge changing work: Change gauges [3] and [4] to 60K and change hose conditions of [3], [4],
and [5].
No.
Check item
Fuel
control
dial
MIN
PC-EPC (F)
valve
9
PC-EPC (R)
valve
MAX
10
LS-EPC valve
Testing oil pressure
J1
(PC-EPC valve output pressure 1)
J2
(PC-EPC valve output pressure 2)
J3
(PC-EPC valve output pressure 3)
J4
(PC-EPC valve output pressure 4)
J5
(PC-EPC valve output pressure 5)
K1
(LS-EPC valve output pressure 1)
K2
(LS-EPC valve output pressure 2)
K3
(LS-EPC valve output pressure 3)
PC200, 200LC, 220, 220LC-8M0
Condition for check
Work-
Left knob
Operation of work
ing
switch
equipment
mode
P
OFF
Arm out relief
Unit
Standard value for new machine
Condition for check
Work-
Left knob
Operation of work
ing
switch
equipment
mode
P
E
All levers in neutral
L
OFF
B
Travel speed: Lo
travel lever in neutral
Travel speed: Mi
Travel lever oper-
P
ated
Travel speed: Hi
Travel lever oper-
ated
Unit
Standard value for new machine
MPa
2
{kg/cm
}
[1]
[2]
[3a]
600K
600K
600K
F pump
R pump
F pump
main
main
servo
H1
H1
H2
H1 : H2 = 1 : 0.6
(Oil pressure ratio)
[1]
[2]
[3b]
600K
600K
60K
F pump
R pump
F pump
main
main
(F)
J1
J2
J3
J4
J5
Approx. 2.9 {Approx. 30}
Approx. 0.7 {Approx. 7}
Approx. 0.78 {Approx. 8}
Approx. 1.7 {Approx. 17.5}
Approx. 1.57 {Approx. 16}
Approx. 2.45 {Approx. 25}
Approx. 0.74 {Approx. 7.5}
0 {0}
SEN06129-01
[4a]
[5]
600K
60K
R pump
Control
servo
H2
Service limit value
[4b]
[5a]
60K
60K
R pump
LS-EPC
(R)
J1
J2
J3
J4
J5
K1
K2
K3
Service limit value
15
30-103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc200lc-8m0Pc220-8m0Pc220lc-8m0

Table of Contents