Komatsu PC200-8M0 Shop Manual page 243

Table of Contents

Advertisement

403 Hydraulic system, Part 3
Solenoid valve
1.
PPC lock solenoid valve
2.
2-stage relief solenoid valve
3.
Swing brake solenoid valve
4.
Travel speed solenoid valve
5.
Travel junction solenoid valve
6.
ATT selector solenoid valve
7.
Connector
8.
Moving core
9.
Coil
10. Spool
11. Block
12. Spring
T:
To tank
A1:
To PPC valve
A2:
To main valve (2-stage relief valve)
A3:
To swing motor
A4:
To L.H. and R.H. travel motors
A5:
To main valve (Travel junction valve)
A6:
To ATT selector valve
P1:
From main pump
ACC: To accumulator
Operation
When solenoid is de-energized
q
Since the signal current does not flow from the
controller, solenoid (9) is de-energized.
For this reason, spool (10) is pushed to the left
by spring (12).
Since port (P) is closed to port (A), pressurized
oil from the main pump does not flow to the
actuator.
At this time, the oil from the actuator is drained
through ports (A) and (T) into the tank.
PC200, 200LC, 220, 220LC-8M0
When solenoid is energized
q
As the signal current flows from the controller
to solenoid (9), solenoid (9) is energized.
Accordingly, spool (10) is pushed to the right.
This operation flows the pressurized oil from
the main pump, through port (P), via inside
spool (10), to port (A), and eventually to the
actuator.
At the same time, port (T) closes, the oil does
not flow to the tank.
SEN06121-00
45
10-403