500 Troubleshooting of hydraulic and mechanical system (H-mode)
H-15 In combined operation of swing and boom RAISE, boom rising speed is low
H-15 In combined operation of swing and boom RAISE, boom rising
speed is low
q
Failure
In combined operations of swing and boom RAISE, boom rising speed is low
q
Related infor-
If boom RAISE speed is also low when it is operated singly, perform troubleshooting for "H- 6 Boom
mation
operation lacks speed or power".
Probable
Malfunction or defective
causes and cri-
1
sealing of swing control
teria
valve (LS select valve)
PC200, 200LC, 220, 220LC-8M0
Cause
LS select valve of swing control valve may malfunction or sealing
may be defective. Check it.
Criteria and troubleshooting procedure
SEN06139-00
25
40-500