SEN06133-00
Failure code [879CKB] Ventilating Sensor Short Circuit
See chapter 80 Others "Failure code [879CKB] Ventilating Sensor Short Circuit".
a Since the ventilating sensor (evaporator temperature sensor) cannot be disconnected with the sensor in-
stalled on the machine, the air conditioner controller or air conditioner unit must be replaced.
Failure code [879DKZ] Sunlight Sensor Open Or Short Circuit
See chapter 80 Others "Failure code [879DKZ] Sunlight Sensor Open or Short Circuit".
Failure code [879EMC] Ventilation Damper Abnormality
See chapter 80 Others "Failure code [879EMC] Ventilation Damper Abnormality".
a Since the vent select servo motor cannot be disconnected on the machine, the air conditioner controller
or air conditioner unit must be replaced.
Failure code [879FMC] Air Mix Damper Abnormality
See chapter 80 Others "Failure code [879FMC] Air Mix Damper Abnormality".
a Since the air mix servo motor connector cannot be disconnected on the machine, the air conditioner con-
troller or air conditioner unit must be replaced.
Failure code [879GKX] Refrigerant Abnormality
See chapter 80 Others "Failure code [879GKX] Refrigerant Abnormality".
4
40-301
301 Troubleshooting by failure code, Part 1
Failure code [879CKB] Ventilating Sensor Short Circuit
PC200, 200LC, 220, 220LC-8M0