Komatsu PC200-8M0 Shop Manual page 433

Table of Contents

Advertisement

102 Testing and adjusting, Part 2
Special functions of machine monitor
Setting and display of user mode (including
KOMTRAX messages for user)
To enter the user mode, press [F6] to display the
"User Menu" screen while the standard screen is
displayed.
a The User Menu has following menus.
ECO Guidance
Machine setting
Maintenance
Monitor setting
Check mail
[KOMTRAX message]
q
There are two types of KOMTRAX message;
one is for the user and the other is for the tech-
nician.
For user: It denotes the messages transmitted
q
from the KOMTRAX base station to users.
Upon receiving a message, the message mon-
itor is displayed on the standard screen. Oper-
ate this "Check mail" when viewing contents of
a message.
For technician: It refers to the messages trans-
q
mitted to the technicians from the KOMTRAX
base station. When a message is received, the
standard screen does not display any informa-
tion relevant to the message received. To view
contents of a message, operate "Display ser-
vice message" of the service menu in the ser-
vice mode.
PC200, 200LC, 220, 220LC-8M0
Display of ECO guidance
When the machine is set in a certain operating con-
dition, the ECO Guidance screen is displayed auto-
matically to urge the operator to perform the
energy-saving operation.
a "ECO Guidance" screen is displayed when the
following conditions are met while this display
function is set to enabled in operator mode.
a Conditions for display:
q
Idle stop guidance
If no lever is operated for a period of at least 5
minutes and the engine keeps running at idle
speed during this period, the guidance on idle
stop is displayed on the monitor. This function
helps reduce unnecessary fuel consumption
by alerting the operator to stop the engine
while waiting for the next operation, or during a
break.
a The lamp for the idle stop guidance goes
out automatically when the lever operation
is resumed, or if the function switch [F5] is
pressed.
Guidance on deterrence of hydraulic relief
If relieving lasts for 3 or more seconds during oper-
ation, guidance on deterrence of hydraulic relief is
displayed on the monitor.
a The lamp for the guidance on deterrence of
hydraulic relief goes out automatically after 10
seconds has passed since it appeared, or if the
function switch [F5] is pressed.
SEN06128-00
13
30-102

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc200lc-8m0Pc220-8m0Pc220lc-8m0