Data Dwell Time - Kenwood NX-5000 Series Common Function Reference

Hide thumbs Also See for NX-5000 Series:
Table of Contents

Advertisement

11 EXTERNAL PORTS
11.2 D-sub 25-pin Connector

Data Dwell Time

Data Dwell Time is the delay time to return to the voice channel when the state of the DTC port or Data PTT port on the
AUX Input port changes from active to inactive. This function can be used when an external device waits to receive an
acknowledgment from the receiving transceiver.
Configuration using KPG-D1/ D1N
Configuring Data Dwell Time (
Avoiding Noise and Chattering on the AUX Input Port (Debounce Time)
Debounce Time is the amount of time to avoid the influence of noise and chattering that occurs on the AUX Input port.
If noise or chattering does not occur while the amount of time configured in Debounce Time elapses, the AUX Input Port
where Debounce is enabled is activated. Using this function prevents the state of the AUX Input port from being erroneously
changed by noise and chattering.
High
Low
Inactive
Active
Configuration using KPG-D1/ D1N
Configuring Debounce Time (
Common FUNC (K, F)/Ver 2.20
Transceiver Settings > Extended Function > AUX > AUX Input)
Noise
Figure 11-1 Debounce Time
Extended Function > AUX > AUX Input)
Chattering
Debounce
Time