Bosch Rexroth IndraMotion MTX 09VRS Manual page 173

Standart nc opeation
Table of Contents

Advertisement

Application Description | Rexroth IndraMotion MTX 09VRS
Fig.10-16:
Profibus DP diagnostics overview screen
The detail view provides additional information on each bus device. The detail
view is available for each slave. The detail view is displayed for the bus device
selected (with black borders). There are three ways of opening the detail view:
Left-click on the slave desired.
Use the arrow keys to select the slaves desired and confirm with <EN‐
TER>.
Use the arrow keys to select the slaves desired and confirm with <F9>.
Press the <F9> key to toggle the overview and detail views.
After you have pressed the key, the detail view will appear on the central and
lower areas of the overview screen. This view provides information on the cur‐
rent state of the bus device, the slave address and the ident number. It also
shows the station status, the current error number transferred by the control in
the event of an error, and the hexadecimal-encoded channel error text.