Bosch Rexroth IndraMotion MTX 09VRS Manual page 224

Standart nc opeation
Table of Contents

Advertisement

212/233
Bosch Rexroth AG | Electric Drives
Extended Functionality
Error
Error Causes
Error Display
Troubleshooting
11.4.5
Size Calculations
Overview
Layout
and Controls
The following causes in the entry can be considered:
Invalid specification,
Nominal size outside the range from 1 to 500 mm and
You have tried to determine a non-preference tolerance.
With all error causes, a uniform error message appears in the lower part of the
form. The focus is automatically reset to the entry field.
Using the <Esc> key, you can reject the latest entry or edit the entry field.
Tasks
The size calculation is most often used for programming radial processing types
if programming takes place in a coordinate system to be transformed - here the
unwinding - and the positions on the circumference are available as angles.
With a given reference diameter (unwinding diameter), you can fulfill the fol‐
lowing tasks:
Conversion of an angular pitch into a circumferential coordinate and
Conversion of a circumferential coordinate into an angular pitch.
The form for size calculations is located on the tab labelled with "Size".
The form provides editable text boxes for the numerical values. Behind the text
boxes that are in the fore and can be considered for a value transfer, pushbut‐
tons for copying purposes are located.
Fig.11-21:
Form for size calculations
Rexroth IndraMotion MTX 09VRS | Application Description