Bosch Rexroth IndraMotion MTX 09VRS Manual page 198

Standart nc opeation
Table of Contents

Advertisement

186/233
Bosch Rexroth AG | Electric Drives
Extended Functionality
Messages of the NC Analyzer
Type
Class
System error_
Critical system error*) ->Critical
Error
- Error
Slight system error*) ->Critical
- Critical error
error
Warning
System warning
- Of the user pro‐
System information
gram
Programmed notice
Information:
- General
Entry error
Operating error
User Reactions to Errors and Messages
Rexroth IndraMotion MTX 09VRS | Application Description
and Controls
Breakpoints cannot be set in this state because the analyzer mode is not active
in the NC analyzer. If you try to switch to analyzer mode, an error message is
shown:
Start NC analyzer
Starting the NC analyzer
Select the channel with the faulty program
The location at which the NC program was stopped due to an error
is shown in the "Program" window of the NC analyzer
The start structure (in case of a possible subroutine stacking in the
NC program) is shown in the "Stack" window
Subroutines can be selected in the "Stack" window and shown using
the F-key <F5> ("Go to start") in the "Program" window to analyze
their program variables
Often the error can be found with this information alone.
However, the least benefit is that the faulty program section is known,
which can then be analyzed in the analyzer mode.
Clear the error source
Test the program
Before carrying out any further machine editing, you should once again test the
program for freedom from errors. The NC analyzer can be a very helpful tool
here as well, as the information (values) of the variables used can be opened
at any time during the program execution.
System and user messages of the NC analyzer are shown in popup windows
with error text classification.
Description
Internal error rendering all further operation of the control impossible.
The NC analyzer closes automatically after confirmation.
Internal error rendering a part section of the control non-functional. The
user can decide whether to continue working with the NC analyzer.
Warning from a part section of the NC analyzer, such as Failed to load
configuration data.
Such as Number of breakpoints exceeded.
Programmed notice from the NC program:
(MSG)
PRN'(0,....)
Such as Variable value invalid
*)
In case of system errors, service must be notified as well.
Fig.11-6:
Error classes NC analyzer
The following steps are possible in case of messages, warnings and "slight"
system errors:
Discard messages or errors as long as it is still possible to work with the
NC analyzer or as long as information on error clearance is provided.
Restart the surface
Contact service

Advertisement

Table of Contents
loading

Table of Contents