Application Description | Rexroth IndraMotion MTX 09VRS

Error Messages

The number of error message and mes‐
sage text
(#9) Invalid value
The value NUL cannot be allocated to a
permanent CPL variable. The old value is
restored.
(#7)The password is invalid.
(#8) The file is write protected.
(#23) It is not possible to set the current
variable value. (IVariable::SetVarValue)
(#86) It is not possible to set the current
variable value. (IVariable::UndefVar)
(#43) It is not possible to set the test func‐
tion mode. (IDryRunMode::SetDryRun‐
Mode)
Messages about problems at setting breakpoints and setting variables for watching
(#12) The number of breakpoints is re‐
stricted. It is not possible to activate a
breakpoint or set a new one.
(#2) It is not possible to perform the re‐
quested operations in the breakpoint dia‐
log.
(#14) It is not possible to create or activate
a breakpoint.
In case of "critical" system errors, the only options left may be:
Restart the surface
Contact service
The probable reason
Messages about the attempt to input some incorrect values
Entry value of the edited variable
does not correspond to the variable
type
The value NUL cannot be allocated
to a permanent CPL variant.
Enter an invalid password for set‐
ting to ignore the general inhibit (in
the «General Inhibit» dialog).
Messages about some forbidden user's actions
An attempt to look through the con‐
tents of read-protected file.
An attempt to edit a single element
of a CPL-constant.
An attempt to edit the whole CPL-
constant.
An attempt to cancel the regime
DryRunMode by the button General
Inhibit ON (F6) in case of working
with NC-emulator.
The number of active breakpoints
has been exceeded.
An attempt to activate, with the help
of the dialog «Breakpoints», one or
some breakpoints of inactive flow
program.
An attempt to change the access
mode of one or some breakpoints,
juxtaposed to variables, of inactive
flow program.
An attempt to set the active break‐
point in the inactive flow program.
Electric Drives
| Bosch Rexroth AG
and Controls
Extended Functionality
Recommendations to a user
Enter a value that corresponds to the required
variable type (see also CPL programming
manual).
Enter a valid value for the permanent CPL
variant or accept the old value.
Enter a valid password or close the dialog.
Continue the work. (It is impossible to look
through the contents of read-protected file).
Proceed the work.
Proceed the work.
Continue the work, because in case of work‐
ing with NC-emulator the regime DryRun‐
Mode is always set, and clicking the button
General Inhibit ON (F6) doesn't cancel this
regime.
Delete or deactivate either one or some active
breakpoints.
Proceed the work or select the flow program
with given breakpoint(s) as active one, then
make desired actions with breakpoint(s).
Proceed the work or select the flow program
with given breakpoint(s) as active one, then
make desired actions with breakpoint(s).
The breakpoint in this case will be inactive
(also in case, when the flow program be‐
comes active).