(2) Selecting the target module in the "Reserved Station Function Enable"
window
Reservation of multiple slave stations can be temporarily cancelled through the
"Reserved Station Function Enable" window all at once.
(a)
Temporarily canceling a reservation
1) Connect a slave station specified as a reserved station to the network.
2) Connect GX Works2 to the CPU module.
3) Start the CC-Link IE Field Network diagnostics from the menu.
[Diagnostics]
4) Click the [Reserved Station Function Enable...] button in the "CC IE Field
Diagnostics" window.
The "Reserved Station Function Enable" window opens.
5) In "Reserved Station List", click the number of the target station. The text
turns red and the background turns orange.
Only reserved stations can be selected. The background of a reserved station
number is displayed in light blue.
6) Clicking the [OK] button will temporarily cancel the reservation.
7) Debug the slave station that has been added.
Chapter 9 CC-LINK IE FIELD NETWORK DIAGNOSTICS
[CC IE Field Diagnostics]
9 - 23