Interrupt Pointer Start No. Enter the start number of an interrupt program (I
PLC Side
Interrupt Pointer Count
Start I/O No.
Intelligent Module
Side
Start SI No.
(2) Precautions
6) Click the [End] button.
Enter the number of interrupt conditions.
Enter the start I/O number of the Simple Motion module.
Enter the start interrupt (SI) number of the Simple Motion
module.
POINT
Using an interrupt program will eliminate the need for describing a start condition in
a program. This leads to reduction in the number of steps and sequence scan time.
(a)
When "Level Detect" is set for "Detection Method" and the interrupt condition is
always met
If the sequence scan takes much longer than the link scan, since interrupt
processing is activated in each link scan, sequence scan time may greatly
increase, resulting in a watchdog timer error of the CPU module.
When "Level Detect" is set for "Detection Method" and the interrupt condition is
always met, do not use interrupt settings and correct the interrupt condition in the
program.
Chapter 7 PARAMETER SETTING
Description
7 - 27
Setting range
).
50 to 255 (Default: Blank)
1 to 16 (Default: Blank)
0000H to 0FE0H
(Default: Blank)
0 to 15 (Default: Blank)