POINT
The synchronous communication function with slave modules excluding servo
amplifiers is supported from the version shown below.
First five digits of SERIAL No.
Before 15092
15092 or later
(Note-1): The serial number can be checked on the "Product Information List" screen in GX Works2.
The link special registers (SW) for synchronous communication function are shown below.
Number
Name
SW01C0
Synchronous
to
communication function
SW01C7
information (each station)
SW01C8
Synchronous/asynchronous
to
operation status information
SW01CF
(each station)
(Note-1)
Slave modules operate in the normal mode
(asynchronous communication mode).
Slave modules operate following the setting.
Stores the setting information of synchronous/asynchronous
communication of the synchronous communication function for
each station.
0: Asynchronous communication mode
1: Synchronous communication mode
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01C0
16 15 14 13 12 11 10
SW01C1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01C2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01C3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01C4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01C5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01C6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
__
__
__
__
__
SW01C7
Each number in the table represents a station No.
__
Stores the synchronous/asynchronous communication operation
status for each station.
0: Asynchronous
1: Synchronous
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01C8
16 15 14 13 12 11 10
SW01C9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01CA
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01CB
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01CC
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01CD
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01CE
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
__
__
__
__
__
SW01CF
Each number in the table represents a station No.
__
8 - 3
Chapter 8 FUNCTIONS
Operation
Description
9
8
7
6
5
4
__
__
__
120 119 118 117 116 115 114 113
is fixed to 0.
9
8
7
6
5
4
__
__
__
120 119 118 117 116 115 114 113
is fixed to 0.
3
2
1
3
2
1

Advertisement