Ac Outlet Box - Fujitsu Eternus DX60 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX60:
Table of Contents

Advertisement

Chapter 2 Hardware
>
2.1 Components
Power unit closeup
Figure 2.16
Figure 2.16 Power unit closeup (drive enclosure)
IMPORTANT
2.1.3

AC outlet box

There are two sizes of AC outlet box: 1U and 2U.
1U AC outlet box has four outlets and two inlets.
2U AC outlet box has twelve outlets and two inlets.
2.1.3.1
AC outlet box (1U)
Figure 2.17 AC outlet box (1U)
P3AM-3042-03ENZ0
ETERNUS DX60/DX80 Disk storage system User Guide
shows a closeup of the power unit.
The power unit has two internal cooling fans.
STATUS LED
Blinks green when AC power is supplied (power cord is connected)
but DC power is turned off.
Glows green when AC power is supplied (power cord is connected)
and DC power is turned on.
Glows orange to indicate a fault has been detected in a fan
or power supply.
The power unit is duplicated. The power cords must be connected to the
inlets of both power units (PSU#0 and PSU#1).
When connecting the power cord right after it is disconnected, wait for
the STATUS LED of the power unit is turned off completely (about 10
seconds) before connecting it again.
Main line switch
54
Inlet
Power cord connects here.
Outlet (OUTPUT)
Power supply code (AC output cable)
connects here.
Inlet (INPUT)
Power supply code (AC Input cable)
connects here.
Copyright 2009 FUJITSU LIMITED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx80

Table of Contents