Chapter 3 Installation
>
3.2 Rack Installation
5-2
3.2.3.2
For 2U
This section describes how to mount the 2U AC outlet box in a rack.
Procedure
1
2
P3AM-3042-03ENZ0
ETERNUS DX60/DX80 Disk storage system User Guide
blank panel
Attach the
AC outlet box
(Rear rack pillars)
Refer to "ETERNUS DX60/DX80 Disk storage system Package Contents" to
confirm there are no missing parts for the rack mount kit.
"ETERNUS DX60/DX80 Disk storage system Package Contents"
Refer
Attach the M5 cage nuts or M5 rack nuts to the rear rack pillar.
Use the M5 cage nuts if the rack pillar holes are square.
Use the M5 rack nuts if the rack pillar holes are round.
Attachment positions
On either side, insert eight M5 cage nuts or M5 rack nuts in the 1st, 3rd, 4th, and 6th
holes above the AC outlet box base line.
M5 cage nut or
(Rear rack pillars)
M5 rack nut
[Left]
6th position
4th position
2U
1U
1U
3rd position
1st position
to the rack pillars using two black M5 screws.
M5 screw
Blank panel
(Front rack pillars)
M5 cage nut or
M5 rack nut
[Right]
6th position
4th position
AC outlet box
AC outlet box
3rd position
1st position
Base line of
AC outlet box
78
M5 screw
End of procedure