Parameters for VD Definition
Item
RAID Level
RAID 0 / RAID 1 / RAID 5 / RAID 6 /
RAID 00 / RAID 10 / RAID 50 / RAID60
Strip Size
8 KB / 16 KB / 32 KB / 64 KB / 128 KB
/ 256 KB / 512 KB / 1024 KB
Access Policy
RW / Read Only / Blocked
Read Policy
Normal / Ahead / Adaptive
Write Policy
WBack / WThru
WrtThru for
Checked / Unchecked
BAD BBU
IO Policy
Direct / Cached
Disk Cache
NoChange / Enable / Disable
Policy
Disable BGI
No / Yes
BGI (Back Ground Initialize) is available only for a RAID5 VD
configured with five or more HDDs.
To use RAID 5 or RAID 6, with an Internal RAID Controller,
you need to install the optional RAID Upgrade Kit.
If the RAID Upgrade Kit is not installed, do not select
"RAID5" that may appear in [RAID Level] box. If selected,
you will fail to save the configuration information. In such a
case, you need to define a VD again from the beginning.
Table 25: Configuration Wizard Parameters
Parameters
Caution
RAID 00, RAID 10, RAID 50, and RAID 60 are not
supported.
Recommended value: 64KB
Recommended value: RW
Recommended value: Normal
WBack: WriteBack
WThru: WriteThru
Select a mode when WriteBack is specified for
Write Policy.
Checked: Normal WriteBack
Unchecked: Constant WriteBack
Recommended value: Checked
Recommended value: Direct
Recommended value: Disable
Specify whether to perform Background Initialize
after creation of VD.
Recommended value: No