Status Lamp

The STATUS lamp is on (green) while the server is operating normally. (The rear panel
also has the STATUS lamp on it.) If the STATUS lamp is off or turns amber and flashes,
it indicates that the server is in abnormal state.
The table below explains the STATUS lamp indication, the meanings, and the
procedures.
If NEC ESMPRO is installed, you can confirm the cause of a
failure by referring to the error log.
If shutdown processing can be performed through the oper-
ating system when you want to restart the system after turn-
ing the power off, restart the system by performing shutdown
processing. If shutdown processing cannot be performed,
restart the system by resetting, forcibly turning the power off,
or disconnecting and then connecting the power cord.
Status lamp
Description
indication
On (green)
The server is operating normally.
Flashing (green) The server is operating with the memory, CPU,
or power supply unit in degraded state.
An uncorrectable memory error has often
occurred.
Off*
The power is off.
POST is in progress.
A CPU error occurred.
A CPU temperature alarm was detected.
A timeout occurred when the time set for the
watchdog timer arrived.
A CPU bus error occurred.
A memory dump request is made.
On (amber)*
A temperature alarm was detected.
A voltage alarm was detected.
All the power supply units failed.
Notes:
Table 33: Status Lamp Indications
Procedure
Check the AC power lamp indication on the
rear panel of the server.
Identify the device in degraded state by using
the BIOS setup utility "SETUP," and replace it
as soon as possible.
Wait for a while. The status lamp turns green
when POST is completed.
Turn the power off and then turn it on. If the
POST screen displays an error message, take
notes of the message, and contact your sales
representative.
Wait until the memory dump is completed.
Check if the internal fans are clean and if the
fan units are firmly connected.
If the status lamp indication does not change
when the fans are normal, contact your sales
representative.
Contact your sales representative.