Suzuki sq-416-420-625 Service Manual page 722

Table of Contents

Advertisement

10B-16 AIR BAG SYSTEM
TABLE A – "AIR BAG" WARNING LAMP COMES "ON" STEADY (Page 1 of 2)
1. From main fuse
2. Ignition switch
.
3. "IG
COIL METER" fuse in J/B
CAUTION:
D When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
D When a check for proper connection is requested refer to "Intermittent and Poor Connections" in this
section.
D When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
STEP
1
1) Ignition switch OFF.
2) Remove and inspect "AIR BAG" fuse.
3) Is fuse good?
2
1) Disconnect SDM.
2) Check proper connection to SDM at
terminal "A16".
3) If OK then check voltage between "A16"
terminal of SDM connector and body
ground with ignition switch ON.
4) Is it 8 V or more?
3
1) Disconnect 16p connector from
combination meter, referring to Section
8C.
2) Check resistance between "A5" terminal
of SDM connector and body ground.
3) Is resistance 1 kf or more?
: Air bag harness
4. "AIR BAG" warning lamp in combination meter
5. "AIR BAG" fuse in "AIR BAG" fuse box
6. Connection detection pin
ACTION
YES
Go to step 2.
Go to step 3.
Substitute a known-
good SDM and
recheck.
7. SDM
7-1. "AIR BAG" warning lamp driver circuit
NO
"BI/R" wire short to ground.
After repair, replace
"AIR BAG" fuse.
"BI/R" wire (between
"AIR BAG" fuse and SDM
connector) open "BI/B" wire
(between ignition switch and
"AIR BAG" fuse) open or short
to ground.
"BI" wire (between combina-
tion meter and SDM connec-
tor) short to ground.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents