ABB ACS800 Series Firmware Manual page 117

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
62.10 DANCER LOAD SETPT
AI1
AI2
AI3
AI5
AI6
FIELDBUS
PARAM 62.33
62.11 DANCER FDBK INPUT
AI1
AI2
AI3
AI5 (0 V)
AI6 (0 V)
AI6 (-10 V)
PARAM 62.34
62.12 TAPER REF SELECT
KEYPAD
AI1
AI2
AI3
AI5
AI6
FIELDBUS
Description
This parameter is only used if the drive is used to control the dancer
loading. If the drive is not controlling the dancer loading
DANCER LOAD REF is not sent to an AO) then this parameter can be
ignored.
The
03.04
DANCER LOAD REF is generated from
LOAD SETPT, taper setpoint, and stall tension setpoint. This value
can be sent to an AO to drive a pressure transducer to load the
dancer.
Analog input AI1 (voltage).
Analog input AI2 (current).
Analog input AI3 (current).
Analog input AI5 (voltage or current).
Analog input AI6 (voltage or current).
06.04
DATASET 3 WORD 1. See chapter
Source selected by
62.33
DAN LD SETPT PTR.
Set to the AI that the dancer feedback device is wired into.
The feedback device should be set up to provide zero output (approx.
0.1...0.5 VDC) at full storage and full output (approx. 9.5...10 VDC) at
no storage. If the feedback device provides a bipolar signal, connect it
up to AI6; the feedback should range from approx. -10 VDC to 9.5
VDC.
Note: If the maximum feedback voltage cannot be attained the
position measuring device should be adjusted to the best resolution.
Loss of resolution may decrease the performance of the overall
tension regulation.
Analog input AI1 (voltage).
Analog input AI2 (current).
Analog input AI3 (current).
Analog input AI5 (voltage).
Analog input AI6 (voltage).
Analog input AI6 (bipolar voltage).
Source selected by
62.34
DAN FDBK PTR.
This parameter is only used if the drive is used to control the dancer
loading. If the drive is not controlling the dancer loading
DANCER LOAD REF is not sent to an AO) then this parameter can be
ignored.
If "KEYPAD" is selected, the value of
the taper maximum. Otherwise, the taper maximum is a scaled value
of the input selected by this parameter and
%TAPER. The range of the scaling is 0...100%.
Control panel. Reference is
Analog input AI1 (voltage).
Analog input AI2 (current).
Analog input AI3 (current).
Analog input AI5 (voltage or current).
Analog input AI6 (voltage or current).
06.05
DATASET 3 WORD 2. See chapter
03.03
Fieldbus
control.
62.13
MAX TAPER/% TAPER is
62.13
MAX TAPER/
62.13
MAX TAPER/% TAPER.
Fieldbus
control.
Actual signals and parameters
105
FbEq
(03.04
DANCER
1
2
3
4
5
6
7
1
2
3
4
5
6
7
(03.04
1
2
3
4
5
6
7