ABB ACS800 Series Firmware Manual page 77

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
02.02 SPEED REF 3
02.03 SPEED REF 4
02.04 SPEED USED REF
02.05 SPEED ESTIMATED
02.06 SPEED MEASURED
02.07 MOTOR TORQUE FILT
02.08 TORQ REF 1
02.09 TORQ REF 2
02.10 TORQ REF 3
02.11 TORQ REF 4
02.12 TORQ REF 5
02.13 TORQ USED REF
02.14 ACTUAL MTR FLUX
02.15 ALARM WORD 1
02.16 ALARM WORD 2
02.17 ALARM WORD 3
02.18 FAULT WORD 1
02.19 FAULT WORD 2
02.20 FAULT WORD 3
02.21 SYSTEM FAULT
02.22 INT FAULT INFO
02.23 LIMIT WORD 1
02.24 MAIN CTRL WORD
02.25 FOLLOWER MCW
02.26 MAIN STATUS WORD
02.27 AUX STATUS WORD
02.28 AUX STATUS WORD 4
02.31 LATEST FAULT
02.32 2. LATEST FAULT
02.33 3. LATEST FAULT
02.34 4. LATEST FAULT
02.35 5. LATEST FAULT
02.36 LATEST WARNING
Description
Ramped and shaped speed reference. 100% corresponds to
EXT REF1 MAXIMUM.
Sum of
02.02
SPEED REF 3 and
100% corresponds to
11.05
Final speed reference for the internal speed controller. 100%
corresponds to
11.05
EXT REF1 MAXIMUM.
Estimated motor speed. 100% corresponds to
MAXIMUM.
Measured motor actual speed (zero when no encoder is used). 100%
corresponds to
11.05
EXT REF1 MAXIMUM.
Filtered motor torque. 100% corresponds to the motor nominal torque. 100 = 1%
Limited sum of M/F torque reference and external torque reference.
100% corresponds to the motor nominal torque.
Speed controller output. 100% corresponds to the motor nominal
torque.
Internal torque reference; after the torque reference selector. 100%
corresponds to the motor nominal torque.
Sum of
02.10
TORQ REF 3 and
100% corresponds to the motor nominal torque.
Sum of
02.11
TORQ REF 4 and
corresponds to the motor nominal torque.
Final torque reference for the internal torque controller. 100%
corresponds to the motor nominal torque.
Flux reference in percent.
A 16-bit data word. See
Table 9
A 16-bit data word. See
Table 10
A 16-bit data word. See
Table 11
A 16-bit data word. See
Table 12
A 16-bit data word. See
Table 13
A 16-bit data word. See
Table 14
A 16-bit data word. See
Table 15
A 16-bit data word. See
Table 16
A 16-bit data word. See
Table 17
A 16-bit data word. See
Table 3
A 16-bit data word. See
Table 18
A 16-bit data word. See
Table 5
A 16-bit data word. See
Table 7
A 16-bit data word. See
Table 6
Fieldbus code of the latest fault. See chapter
codes.
Fieldbus code of the 2nd latest fault.
Fieldbus code of the 3rd latest fault.
Fieldbus code of the 4th latest fault.
Fieldbus code of the 5th latest fault.
Fieldbus code of the latest warning.
25.03
SPEED CORRECTION.
EXT REF1 MAXIMUM.
11.05
EXT REF1
24.08
LOAD COMPENSATION.
24.09
TORQ TRIM. 100%
on page 154.
on page 154.
on page 155.
on page 155.
on page 156.
on page 156.
on page 157.
on page 158.
on page 159.
on page 149.
on page 159.
on page 151.
on page 152.
on page 152.
Fault tracing
Actual signals and parameters
65
FbEq
11.05
200 = 1%
200 = 1%
200 = 1%
200 = 1%
200 = 1%
100 = 1%
100 = 1%
100 = 1%
100 = 1%
100 = 1%
100 = 1%
10 = 1%
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
for the
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-u2Acs800-u7Acs800-u4

Table of Contents