58

Default control connections

The figure below shows the external control connections for the Tension macro(s).
The markings of the terminals on the RMIO board are visible.
A
A rpm
Application macros
X20
1
VREF
Reference voltage -10 VDC
2
GND
1 kOhm < R
X21
1
VREF
Speed Reference 0(2)...10 V
1 kOhm < R
2
GND
3
AI1+
Speed reference 0(2)...10 V, R
4
AI1-
5
AI2+
Tension Fdbk Input. 0(4)...20 mA, R
100 Ohm
6
AI2-
7
AI3+
Tension Setpoint. 0(4)...20 mA, R
Ohm
8
AI3-
9
AO1+
Output Current 0(4)...20 mA
current, R
10
AO1-
L
11
AO2+
Output Speed 0(4)...20 mA
speed, R
12
AO2-
L
X22
1
DI1
Stop/Start
2
DI2
By default not in use
3
DI3
Tension Ctrl Enable.
4
DI4
By default not in use
5
DI5
Diameter Reset
6
DI6
Fault Reset
7
+24 V
+24 VDC, max. 100 mA
8
+24 V
9
DGND1 Digital ground
10
DGND2 Digital ground
11
DIIL
Estop Input
X23
1
+24 V
Auxiliary voltage output, non-isolated,
24 VDC, 250 mA
2
GND
X25
1
RO11
2
RO12
Ready
3
RO13
X26
1
RO21
2
RO22
Running
3
RO23
X27
1
R031
2
R032
Fault
3
R033
< 10 kOhm
L
< 10 kOhm
L
> 200 kOhm
in
in
= 100
in
0...motor nom.
=
< 700 Ohm
0...motor nom.
=
< 700 Ohm
=