Adapt Prog Ctrl - ABB ACS800 Series Firmware Manual

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
0...20000
70.08 MASTER SIGNAL 2
0...20000
70.09 MASTER SIGNAL 3
0...20000
70.10 M/F COMM DELAY
0...8388607 ms
70.11 M/F COM LOSS CTRL
NO ERR CHK
RAMP STOP
COAST STOP
70.12 CHANNEL 3 ADDR
1...254
70.13 NUM OF TQ FOLLWR
0...4

83 ADAPT PROG CTRL

83.01 ADAPT PROG CMD
STOP
RUN
EDIT
83.02 EDIT COMMAND
NO
Description
Setting range.
Signal pointer for high speed dataset communications to followers as
Reference 1 (speed reference).
Setting range.
Signal pointer for high speed dataset communications to followers as
Reference 2 (torque reference).
Setting range.
The delay time before a M/F COMM LOSS is declared.
Setting range.
Action the drive will take when a M/F COMM LOSS is detected.
CH2 communication loss is not checked.
The drive will ramp to a stop and show a warning.
The drive will fault, remove the run command and coast to a stop.
Node address for channel 3. No two nodes on-line may have the same
address. Typically the setting needs to be changed when the drive is
connected in a ring which consists of several drives and a PC with the
DriveWindow® program running.
Address.
This parameter defines the number of torque follower drives that are
being used. This will scale the torque reference to the total available
motor torque when using open or closed loop torque control. The
application assumes the motors to be identically rated.
Setting range.
Control of the Adaptive Program execution. For more information, see
Adaptive Program Application Guide (code: 3AFE64527274
[English]).
Selects the operation mode for the Adaptive Program.
Stop. The program cannot be edited.
Run. The program cannot be edited.
Stop to edit mode. Program can be edited.
Selects the command for the block placed in the location defined by
83.03
EDIT BLOCK. The program must be in editing mode (see
83.01
ADAPT PROG CMD).
Home value. The value automatically restores to NO after an editing
command has been executed.
FbEq
1 = 1
1 = 1
1 = 1
1 = 1 ms
1
2
3
1 = 1
1 = 1
1
2
3
1
Actual signals and parameters
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-u2Acs800-u7Acs800-u4

Table of Contents