98 OPTION MODULES

98.01 ENCODER MODULE
NTAC
NO
RTAC-SLOT1
RTAC-SLOT2
RTAC-DDCS
RRIA-SLOT1
RRIA-SLOT2
RRIA-DDCS
RTAC03-SLOT1
RTAC03-SLOT2
RTAC03-DDCS
98.02 FIELDBUS MODULE
NO
FIELDBUS
ADVANT
Actual signals and parameters
Description
Activation of the optional I/O extension modules and fieldbus adapter.
For more information on option modules, see the module manuals.
These parameter settings will remain the same even if the macro is
changed.
Activates the communication to the optional pulse encoder module.
Communication active. Module type: NTAC module. Connection
interface: Fibre optic DDCS link.
Note: Module node number must be set to 16. For directions, see
Installation and Start-up Guide for NTAC-0x/NDIO-0x/NAIO-0x
Modules (Code: 3AFY58919730 [English]).
Inactive.
Communication active. Module type: RTAC. Connection interface:
Option slot 1 of the drive.
Communication active. Module type: RTAC. Connection interface:
Option slot 2 of the drive.
Communication active. Module type: RTAC. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set to 16. For directions, see
User's Manual for RDIO Module (Code: 3AFE64485733 [English]).
Communication active. Module type: RRIA. Connection interface:
option slot 1 of the drive.
Communication active. Module type: RRIA. Connection interface:
option slot 2 of the drive.
Communication active. Module type: RRIA. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set at 16. For directions, see
RRIA-01 Resolver Interface Module User's Manual [3AFE68570760
(English)].
Communication active. Module type: RTAC. Connection interface:
option slot 1 of the drive.
Communication active. Module type: RTAC. Connection interface:
option slot 2 of the drive.
Communication active. Module type: RTAC. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set at 16. For directions, see
RRIA-01 Resolver Interface Module User's Manual [3AFE68570760
(English)].
Activates the external serial communication and selects the interface.
See chapter
Fieldbus
control.
No communication.
The drive communicates via a fieldbus adapter module in option slot 1
of the drive, or via CH0 on the RDCO board. See also group
FIELDBUS
DATA.
The drive communicates with an ABB Advant OCS system via CH0 on
the RDCO board (optional). See also group
51
70 DDCS
CONTROL.
FbEq
0
1
2
3
4
5
6
7
8
9
10
1
2
3