Dataset Output Sel; Hardware Specific - ABB ACS800 Series Firmware Manual

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

130
No.
Name/Value
0...10000
90.09 DATA 5 WORD 3
0...10000

92 DATASET OUTPUT SEL

92.01 DATA 2 WORD 1
0...10000
92.02 DATA 2 WORD 2
0...10000
92.03 DATA 2 WORD 3
0...10000
92.04 DATA 4 WORD 1
0...10000
92.05 DATA 4 WORD 2
0...10000
92.06 DATA 4 WORD 3
0...10000
92.07 DATA 6 WORD 1
0...10000
92.08 DATA 6 WORD 2
0...10000
92.09 DATA 6 WORD 3
0 ...10000

95 HARDWARE SPECIFIC

95.01 FAN SPD CTRL MODE
CONST 50 Hz
RUN/STOP
CONTROLLED
95.05 ENA INC SW FREQ
NO
YES
Actual signals and parameters
Description
Setting range.
Pointer for the parameter to which the value of the fieldbus is written.
Setting range.
Addresses of the parameters that are to be sent over the fieldbus.
Refer to the
Table 2
on page
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Pointer for the parameter that is sent over the fieldbus.
Setting range.
Fan speed control, sine filter application etc.
Selects the speed control of the optional inverter cooling fan.
Fan is running at constant frequency of 50 Hz when powered.
Drive stopped: Fan is running at constant frequency of 10 Hz.
Drive running: Fan is running at constant frequency of 50 Hz.
The speed of the fan is determined from IGBT temperature vs. fan
speed curve.
Activates the minimum switching frequency limitation for Ex-motor
applications.
Inactive.
Active. Minimum switching frequency limit is set to 2 kHz. Used with
motors with an ATEX certification based on 2 kHz minimum switching
frequency.
147
for more default information.
FbEq
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
0
1
2
0
65535