ABB ACS800 Series Firmware Manual page 123

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
63.11 TENSION FDBK INPUT
AI1
AI2
AI3
AI5
AI6
PARAM 63.34
63.12 TAPER REF SELECT
KEYPAD
AI1
AI2
AI3
AI5
AI6
FIELDBUS
63.13 MAX TAPER/% TAPER
0...100%
63.14 MAXIMUM TENSION
1...99999 N
1...99999 lb
Description
Set to the AI that the tension feedback device is wired into.
The feedback device should be set up to provide zero output (approx.
0...0.3 VDC) at zero tension and full output (approx. 9.7...10 VDC) at
maximum tension.
Hint: To apply maximum tension, feed a rope or strap through the
machine and apply enough weight at the end of the rope to give the
maximum tension. Once this is done, adjust the device's output for
10 VDC. If the maximum output is less than the above recommended
values, it is recommended to review the device's range of operation
for correct sizing. Second, check for correct installation and orientation
of the device. Finally, if the application is correct, use an analog
amplifier to increase the signal to the above recommended values.
Note: Usage of a reduced feedback signal will result in loss of
resolution. A loss of resolution may decrease the performance of the
overall tension regulation. Use of the scaling parameter for the analog
input does not improve signal resolution.
Note: Use of properly rated tension transducers (loadcells) for the
application is required. The transducers should be sized as close to
the application's required maximum tension as possible. For example,
using transducers rated for 400 lbs tension is not acceptable for
applications in which web tension ranges from 5 to 40 lbs.
Analog input AI1 (voltage).
Analog input AI2 (current).
Analog input AI3 (current).
Analog input AI5 (voltage or current).
Analog input AI6 (voltage or current).
Source selected by
63.34
TEN FDBK PTR.
If "KEYPAD" is selected, the value of
the taper maximum. Otherwise, the taper maximum is a scaled value
of the input selected by this parameter and
%TAPER. The range of the scaling is 0...100%.
Control panel. Reference is
Analog input AI1 (voltage).
Analog input AI2 (current).
Analog input AI3 (current).
Analog input AI5 (voltage or current).
Analog input AI6 (voltage or current).
06.05
DATASET 3 WORD 2. See chapter
If MAX TAPER/%TAPER is not 0%,
as
03.13
ROLL DIAMETER increases. At
DIAMETER, the taper setpoint is 0%. At
DIAMETER, the taper setpoint is the 63.13 MAX TAPER/%TAPER *
the value from
63.12
TAPER REF SELECT.
Setting range.
This parameter scales the value that comes in on the selected input
given by
63.10
TENSION SETPOINT. This scaled value is
TENSION SETPOINT.
Setting range.
63.13
MAX TAPER/% TAPER is
63.13
MAX TAPER/
63.13
MAX TAPER/% TAPER.
Fieldbus
control.
03.08
TENSION REF decreases
65.01
MIN CORE
65.02
MAX ROLL
Actual signals and parameters
111
FbEq
1
2
3
4
5
6
1
2
3
4
5
6
7
1 = 1%
03.07
1 = 1 N
1 = 1 lb