Line Modules Booksize Compact
5.2 Smart Line Modules Booksize Compact
Smart Line Module Booksize Compact
Rated power
DC link currents
Rated DC link current
at 600 V
DC link current
at 540 V
at DC 600 V; S6 duty (40 %)
at DC 600 V; peak current
Current carrying capacity
DC link busbars
Reinforced DC link busbars
24 V busbar
Electronics current consumption at 24 V DC
For internal air cooling
For cold plate cooling
Total power loss internal air cooling
(including electronics losses, see Power loss
tables (Page 756))
Power loss distribution for cold plate
(including electronics losses)
Internal
External
DC link capacitance
Smart Line Module
Drive line-up, max.
Power factor
Circuit breaker (IEC 60947 and UL)
Rated short-circuit current SCCR
Max. total cable length
4)
Cooling methods
Cooling air requirement
with internal air cooling
Max. permissible heat-sink temperature
cold plate
Sound pressure level
Weight
The specified power ratings apply to the line voltage range from 380 V to 480 V.
1)
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
2)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker – and the Line
3)
Module in the drive system.
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module
4)
344
6SL3430–
kW
A
DC
A
DC
A
DC
A
DC
A
DC
A
DC
A
DC
A
DC
A
DC
W
W
W
μF
μF
cos φ
kA
3)
m
/h
3
°C
dB(A)
kg
6TE21-6AA.
16
27
30
35
59
100
150
20
0.95
0.85
187.8
56.6
130
705
6000
0.98
See Chapter Overcurrent protection using line fuses
and circuit breakers (Page 51)
65
See Chapter Combination options, Line Modules with
line reactors and line filters (Page 135)
Internal air cooling
Cold plate cooling
56
71
< 60
5.3
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Booksize Power Units