Cabinet design and EMC Booksize
12.7 Connection systems
Shield support with shield plate supplied
A shield plate is always provided with the screw version of the motor connector. The shield
of a prefabricated motor power cable should be preferably connected at this shield plate that
is provided.
Table 12- 26 Possible mounting options for the shield connection plate with recommended conductor
Shield plate supplied for the motor connector
Version 2: Lengths in mm and (inches)
a = 60
b = 12
c = 77
d = 10
The shield plate can be mounted at various angles at the motor connector using two screws
(M4) that are provided (tightening torque: 1.8 Nm).
724
stripped lengths
(2.36
)
-0/+2
-0/+0.08
(0.47
)
±0.5
±0.20
(3.03
)
-1/+2
-0.04/+0.08
(0.39
)
±0.5
±0.20
Version 1: Lengths in mm and (inches)
a = 45
(1.77
)
-0/+2
-0/+0.08
b = 12
(0.47
)
±0.5
±0.20
c = 57
(2.24
)
-1/+2
-0.04/+0.08
d = 10
(0.39
)
±0.5
±0.20
Version 3: Lengths in mm and (inches)
a = 67
(2.64
)
-0/+2
-0/+0.08
b = 12
(0.47
)
±0.5
±0.20
c = 82
(3.23
)
-1/+2
-0.04/+0.08
d = 10
(0.39
)
±0.5
±0.20
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8