Connection Systems; Drive-Cliq Signal Cables; Overview - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet design and EMC Booksize

12.7 Connection systems

Table 12- 10 Recommendation for Control Supply Module
Rated output cur-
Phases
rent [A]
20
3
Danger to life through a hazardous voltage when connecting an unsuitable power supply
Touching live components can result in death or severe injury.
• Connect the ground potential to the PE conductor connection.
• Mount the power supply close to the drive lineup.
12.7
Connection systems
Note
Cables for UL applications
For UL applications, only 60/75 °C copper cables may be used.
12.7.1

DRIVE-CLiQ signal cables

12.7.1.1

Overview

To connect DRIVE-CLiQ components, various pre-assembled and non-assembled DRIVE-
CLiQ signal cables are available. The following pre-assembled DRIVE-CLiQ signal cables
will be discussed in more detail in the next sections:
● Signal cables without 24 V cores with RJ45 connectors
● MOTION-CONNECT signal cables with DRIVE-CLiQ connectors
● MOTION-CONNECT signal cables with DRIVE-CLiQ connector and M12 socket
704
Input voltage range [V]
3-phase 380 V AC -10 % (-15 %
< 1 min) to 480 V AC +10%
DC 300 ... 800
WARNING
Ideally, they should be mounted on a common mounting plate. If different mounting
plates are used, they must be electrically connected in compliance with the
Configuration Manual, "EMC installation guideline".
Short-circuit current [A]
< 24
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Article No.
6SL3100-1DE22-0AA.
Booksize Power Units