Connection Example; Meaning Of Leds - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
6.5.3

Connection example

Figure 6-91
Connection example for Motor Module Liquid Cooled (200 A)
6.5.4

Meaning of LEDs

Table 6- 51
Meaning of LEDs
Status
RDY
DC LINK
Off
Off
Green
--
1)
Orange
Red
450
Description, cause
The electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is present.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is outside the permissible tolerance
range.
Remedy
Check the line supply volt-
age.