Motor And Brake Connection - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
6.5.2.2

Motor and brake connection

Table 6- 47
X1 Motor connection
For ring cable lugs without insulation (Page 732)
1)
Table 6- 48
X11 brake connector
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be installed
externally.
446
Terminal
Technical data
U2
Threaded bolts M8 / 13 Nm
V2
W2
- (BR-)
PE connection
Threaded hole M8 / 13 Nm
Terminal
Technical data
+ (BR+)
Voltage 24 V DC
Max. Load current 2 A
- (BR-)
Minimum load current 0.1 A
Type: Spring-loaded terminal 2 (Page 730)
The brake connector is part of the prefabricated cable.
1)
1)
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents