Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
6.5.2.2
Motor and brake connection
Table 6- 47
X1 Motor connection
For ring cable lugs without insulation (Page 732)
1)
Table 6- 48
X11 brake connector
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be installed
externally.
446
Terminal
Technical data
U2
Threaded bolts M8 / 13 Nm
V2
W2
- (BR-)
PE connection
Threaded hole M8 / 13 Nm
Terminal
Technical data
+ (BR+)
Voltage 24 V DC
Max. Load current 2 A
- (BR-)
Minimum load current 0.1 A
Type: Spring-loaded terminal 2 (Page 730)
The brake connector is part of the prefabricated cable.
1)
1)
Booksize Power Units