3. Fix the DC link adapter (1.8 Nm) with the pre-
viously removed DC link screws
When installing using two screws, use the right-
handholes
Observe the special issues when using rein-
1)
forced DC link busbar (refer below)
Result:
Installed DC link adapter and 24 V terminal
adapter
Danger to life through electric shock when touching the DC link busbars
Contact with live parts can result in death or serious injury.
• The DC link adapters must be installed so that after closing the DC link cover they
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
.
DANGER
cannot be touched!
4. Remove the DC link side cover, install the 24 V
.
terminal adapter (if required) and close the pro-
1)
tective cover until it audibly clicks into place.
Accessories
11.5 DC link adapter