12.7.2.2

Comparison of MOTION-CONNECT power cables

MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. MOTION-
CONNECT 800PLUS power cables fulfill all of the high mechanical requirements for use in
tow chains. They are resistant to cutting oils.
Table 12- 16 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables
Power cable
Approvals
VDE
1)
cURus or UR/CSA
2)
In conformance with RoHS
Rated voltage V
/V in accordance with EN 50395
0
Supply conductors
Signal conductors
Test voltage, rms
Supply conductors
Signal conductors
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. traversing velocity
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
The registration number is printed on the cable jacket.
1)
The UR/CSA file number is stamped on the cable sheath.
2)
Characteristic curves for accelerating can be found in Catalog "PM21" in Chapter "MOTION-CONNECT connection
3)
system."
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
MOTION-CONNECT 500
Yes
Yes
Yes
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-20 ... +80 °C
0 ... 60 °C
50 N/mm
2
20 N/mm
2
5 x D
max
approx. 18 x D
max
30 °/m absolute
100000
30 m/min
2 m/s
2
CFC/silicon-free
EN 60811-2-1
(mineral oil only)
PVC
DESINA color, orange RAL 2003
EN 60332-1-1 to 1-3
Cabinet design and EMC Booksize
12.7 Connection systems
MOTION-CONNECT 800PLUS
Yes
Yes
Yes
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-50 ... +80 °C
-20 ... +60 °C
50 N/mm
2
20 N/mm
2
4 x D
max
approx. 8 x D
max
30 °/m absolute
10 million
Up to 300 m/min
50 m/s
(3 m)
2
3)
CFC/halogen/silicon-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color, orange, RAL 2003
EN 60332-1-1 to 1-3
713