Table 12- 44
Motor Module
Single Motor Module 3 A
Single Motor Module 5 A
Single Motor Module 9 A
Single Motor Module 18 A
Single Motor Module 30 A
Single Motor Module 45 A
Single Motor Module 60 A
Single Motor Module 85 A
Single Motor Module 132 A
Single Motor Module 200 A
Double Motor Module 3 A
Double Motor Module 5 A
Double Motor Module 9 A
Double Motor Module 18 A
Overview of typical power losses at the rated operating point
Table 12- 45
Motor Module
Single Motor Module 3 A
Single Motor Module 5 A
Single Motor Module 9 A
Single Motor Module 18 A
Single Motor Module 30 A
Single Motor Module 45 A
Single Motor Module 60 A
Single Motor Module 85 A
Single Motor Module 132 A
Single Motor Module 200 A
Double Motor Module 3 A
Double Motor Module 5 A
Double Motor Module 9 A
Double Motor Module 18 A
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Coefficients to calculate the power loss in the control cabinet for externally cooled
Motor Modules for typical applications
Typical power losses in the control cabinet for operation at the rated operating point
for internally and externally cooled Motor Modules
Cabinet design and EMC Booksize
12.12 Power losses of the components
a [W]
S
[W/A]
1
10
2,30
10
2,30
10
2,30
10
2,34
16
1,29
21
1,31
27
1,37
32
1,37
50
1,06
50
1,06
15
1,37
15
1,37
15
1,37
18
1,56
P
[W]
Vn
internal air cooling
26
36
60
140
263
382
550
772
1257
2032
54
81
152
281
S
[W/A
]
2
2
0,100
0,100
0,100
0,101
0,057
0,015
0,006
0,006
0,004
0,004
0,240
0,240
0,240
0,056
P
[W]
Vn
external air cooling
18
24
39
85
106
110
130
192
260
422
28
41
79
110
769