Siemens SINAMICS S120 Manual page 479

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Double Motor Modules Booksize Compact
DC link current I
d rated
DC-link voltage
(up to 2000 m above sea level)
DC-link capacitance
Overvoltage trip
Undervoltage trip
1)
Electronics power supply
Electronics current consumption at 24 VDC
For internal air cooling
For cold plate cooling
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
Max. current motor brake
Unit rating
2)
Based on I
(600 V, 8 kHz)
n
Based on I
H
Total power loss
(including electronics losses, see Power loss ta-
bles (Page 756))
Internal air cooling
Cold plate int./ext.
Max. pulse frequency
without derating
with derating
Output frequency
Sound pressure level with internal air cooling
Cooling methods
Cooling air requirement with internal air cooling
Max. permissible heatsink temperature
For internal air cooling
For cold plate cooling
Ventilation clearances
above/below
Weight
Default setting for 400 V line supplies, undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
1)
parameterized line voltage
Rated power of a typical standard induction motor at 400 V 3 AC
2)
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
6SL3420-
2TE11-7AA.
A
4.1
DC
V
DC
μF
165
V
DC
V
DC
V
DC
A
1.15
DC
A
0.9
DC
A
100
A
150
A
20
A
2 x 2
kW
2 x 0.9
kW
2 x 0.8
W
114 (8 kHz)
W
42/72
kHz
kHz
Hz
dB(A)
< 60
Internal air cooling with mounted fan
Cold plate cooling
m
/h
29.6
3
° C
84
° C
71
mm
kg
3.4
Motor Modules Booksize Compact
7.8 Technical data
2TE13-0AA.
2TE15-0AA.
7.2
12
510 ... 720
165
165
820 ± 2 %
380 ± 2 %
24 (20.4 ... 28.8)
1.15
1.15
0.9
0.9
100
100
150
150
20
20
2 x 2
2 x 2
2 x 1.6
2 x 2.7
2 x 1.4
2 x 2.3
134 (8 kHz)
194 (8 kHz)
44/90
59/135
8
16
0 ... 550
< 60
< 60
29.6
29.6
88
93
75
75
≥ 80
3.4
3.4
479

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents