Accessories
11.8 Spacing bolt for Booksize Compact components
11.8
Spacing bolt for Booksize Compact components
To increase the mounting depth of modules in Booksize Compact format, use spacer bolts
(article number: 6SL3462-1CC00-0AA0). In this way, it is possible to combine modules in
Booksize Compact format directly with booksize modules with internal air cooling.
Table 11- 28 Number of spacing bolts and holes for various module widths
Module width in [mm]
50
75
100
Mounting the spacing bolts with press-in nuts
● Inserting M6 press-in nuts into the mounting panel
● Distance 25 mm ± 0.15 mm for module width 75 mm
● Distance 50 mm ± 0.15 mm for module width 100 mm
①
②
Figure 11-43 Mounting the M6 press-in nuts on the rear of the mounting panel
As an alternative to press-in nuts, you can secure spacing bolts with M6 nuts to the rear of
the mounting panel.
662
Number of spacing bolts
2
4
4
M6 press-in nuts
Mounting wall
Number of holes/press-in nuts
2
4
4
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8