Mounting; Installation On Components That Are 50 Mm And 100 Mm Wide - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Accessories
11.4 DC link rectifier adapter for Booksize format
11.4.5

Mounting

Danger to life through electric shock if the cutout in the protective cover has been broken
out
Live components are open and accessible if the 24 V terminal adapter or the DC link infeed
adapter are removed. Touching live components can result in death or severe injury.
• Replace the protective cover with the broken out cutouts by a new protective cover.
11.4.5.1

Installation on components that are 50 mm and 100 mm wide

Required tools:
● Slot-head screwdriver (1 x 5.5) for releasing the protective cover
● Torx T10 screwdriver to fasten the 24 V terminal adapter
● Torx screwdriver T20 for DC link screws (Torx slot)
● Pliers for breaking out the cutouts
Table 11- 16 Removing the DC link busbars
1. Release and open the protective
cover.
632
WARNING
2. Remove the upper left-hand screw
and the DC link bridge
3. Remove the lower left-hand screw
and the DC link bridge
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8