Siemens SINUMERIK 840D sl Function Manual page 111

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
Timing when the limit value is exceeded
If the safe operating stop function is active, when the limit value is exceeded the
response is as follows:
Shutdown
speed
Fig. 6-4
Table 6-2
Explanation of the diagram
Time
Explanation
t
The position control clock cycle, defined by the following MDs:
1
for 840D sl:
MD 10050: $MN_SYSCLOCK_CYCLE_TIME
MD 10060: $MN_POSCTRL_SYSCLOCK_TIME_RATIO
t
Monitoring clock cycle, defined by the following MDs:
2
for 840D sl:
MD 10090: $MN_SAFETY_SYSCLOCK_TIME_RATIO
for SINAMICS S120:
r9500 SI motion, monitoring clock cycle
t
Time until the standstill tolerance value is exceeded
3
t
Time until it has been detected that the standstill tolerance value has been exceeded
4
(typical 0.5 monitoring clock cycles, maximum 1 monitoring clock cycle + 1 position controller
clock cycle)
t
Response time required to initiate the configured stop response
5
(typical 1.5 monitoring clock cycles, maximum 2 monitoring clock cycles + 1 position controller
clock cycle)
t
Time until the initiated stop response starts
6
(typical 2 position controller clock cycles, maximum 2 position controller clock cycles)
t
Time required to reach the shutdown speed for STOP B.
7
t
Time required to stop the axis for a STOP B.
8
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
d) Transition from STOP B to
n
STOP A (pulse cancellation)
Tolerance
exceeded b)
Fault a)
Standstill
= =
tolerance
t
3
t
4
t
5
Timing when the limit value is exceeded for SBH
Safety Functions Integrated in the System/Drive
6.2 Safe operating stop (SBH)
c) Start of the stop response
STOP B
d)
not
t
to scale
1
t
2
t
6
t
7
t
8
t
9
STOP A
s
t
6-111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents