03.06
Explanation
Remedy
C01711
Response
Acknowledgement
Explanation
Remedy
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
The drive is stopped using STOP C (retraction motion). "Safe operating
stop" (SBH) is activated after the parameterized timer has expired.
Possible causes:
– Stop request from the higher-level control
– Subsequent response of message C01714 "SI motion:
Safely-reduced speed exceeded".
– Subsequent response of message C01715 "SI motion: Safe limit
position exceeded".
See also: p9554
Remove the cause of the fault on the control and carry-out a power on.
– Carry-out diagnostics for message C01714.
SI motion: Defect in a monitoring channel
NONE
IMMEDIATELY (POWER ON)
For a crosswise comparison, the drive found a difference between input
data or results of the monitoring functions and initiated a STOP F. One
of the monitoring functions no longer functions reliably, i.e. safe
operation is no longer possible.
If at least one monitoring function is active, then after the
parameterized timer has expired, message C01701 "SI motion: STOP
B initiated" is output.
The message value that resulted in a STOP F is displayed in r9725.
Message value: (r9749, decimal):
Value that resulted in the STOP F.
See also: p9555, r9725
The message value contained in r9725 is described in message 27001
of the higher-level control.