Siemens SINUMERIK 840D sl Function Manual page 474

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.3 Safety messages for SINAMICS S120
F30655
Response:
Acknowledgement
Explanation
Remedy
F30656
Response:
Acknowledgement
Explanation
Remedy
10-474
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
SI MM: Align the monitoring functions
OFF2
IMMEDIATELY (POWER ON)
An error has occurred when aligning the Safety Integrated monitoring
functions on the Control Unit (CU) and Motor Module (MM). Control
Unit and Motor Module were not able to determine a common set of
supported SI monitoring functions.
– DRIVE-CLIQ communications has an error or failed.
– Safety Integrated software releases on the Control Unit and the
Motor Module are not compatible with one another.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, hexadecimal):
Only for internal Siemens troubleshooting.
Carry-out a POWER ON (power off/on) for all components
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.
– Check the electrical cabinet design and cable routing for EMC
compliance.
SI MM: Incorrect Motor Module parameter
OFF2
IMMEDIATELY (POWER ON)
When accessing the Safety Integrated parameters for the Motor
Module (MM) on the CompactFlash Card, an error has occurred.
Note:
This fault results in a STOP A.
Fault value (r0949, decimal):
129:
Safety parameters for the Motor Module corrupted.
131:
Internal software error on the Control Unit.
255:
Internal Motor Module software error.
Re-commission the safety functions.
– Upgrade the Control Unit software.
– Upgrade the Motor Module software.
– Replace the CompactFlash Card.
© Siemens AG, 2006. All rights reserved