System Features

3.3 System requirements

3.3
System requirements
S Software option "SINUMERIK Safety Integrated"
SI-Basic (including 1 axis/spindle, up to 4 SPL I/Os)
SI-Comfort (including 1 axis/spindle, up to 64 SPL I/Os)
SI-axis/spindle (in addition for each axis /spindle)
SI axis/spindle package (in addition, 15 axes/spindles)
S SINUMERIK 840D sl; software release:
From 1.3.1 for safety functions integrated in the drive (SH/SBC via terminals,
Chapter 4)
From 1.3.2 for safety functions integrated in the system (Chapters 5 to 7)
S SINUMERIK 840D sl; all NCU types can be used
S The measuring circuit cables must comply with the specifications of the SINAM-
ICS S120.
S Drive, SINAMICS S120
S The safety-related devices/modules are open-type devices/modules corre-
sponding to UL 50 and in order to provide protection against mechanical dam-
age, they should be accommodated in enclosures/cabinets with degree of
protection IP54 according to EN 60529.
S The state of a deleted/clear safety-related input or output (i.e. the state logical
"0" of an SGE/SGA and electrical "low" of an associated I/O terminal) or the
state of a drive where the pulses are cancelled that can be achieved by the
user as well by the fault response of the "SINUMERIK Safety Integrated" sys-
tem, is defined as the so-called "fail-safe state". This is the reason that the sys-
tem is only suitable for applications where this state corresponds to the safe
state of the process controlled by SINUMERIK Safety Integrated.
S Drives with slip cannot be used for SE and SN.
The following specifically applies for fail-safe SIMATIC modules:
S STEP7 F configuration tool (F Configuration Pack) as supplement to STEP7
This F configuration tool is required so that ET 200 F modules can be integra-
ted into the HW configuration.
The F configuration tool can be downloaded from the A&D Service&Support
pages under the Subject F-Configuration-Pack. Which F configuration tool
can be used for which STEP7 version is also specified there.
When using ET 200 F modules it should be noted that a version of the F config-
uration tool should be used that already supports the module.
Which modules can be configured with which versions that can be downloaded
are also specified in the download area.
3-42
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
6FC5800 – 0AM63 – 0YB0
6FC5800 – 0AM64 – 0YB0
6FC5800 – 0AC70 – 0YB0
6FC5800 – 0AC60 – 0YB0
© Siemens AG, 2006. All rights reserved
03.06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents