Diagnostics
10.3 Safety messages for SINAMICS S120
Remedy
F30649
Response:
Acknowledgement
Explanation
Remedy
F30650
Response:
Acknowledgement
Explanation
10-472
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
Check the PROFIsafe address in the higher-level control and Motor
Module.
– Carry-out a POWER ON (power off/on) for all components
– Upgrade the Motor Module software.
SI MM: Internal software error
OFF2
IMMEDIATELY (POWER ON)
An internal error in the Safety Integrated software on the Motor Module
has occurred.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, hexadecimal):
Only for internal Siemens troubleshooting.
Carry-out a POWER ON (power off/on) for all components
– Re-commission the Safety Integrated function and carry-out a
power on.
– Upgrade the Motor Module software.
– Contact the Hotline.
– Replace the Motor Module.
SI MM: Acceptance test required
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function on the Motor Module requires an
acceptance test.
Note:
This fault results in a STOP A.
Fault value (r0949, decimal)
130:
No safety parameters available for the Motor Module.
1000:
Reference and actual checksum in the Motor Module are not identical
(boot).
– At least one checksum-checked piece of data is defective.
2000:
Reference and actual checksum on the Motor Module are not identi-
cal (commissioning mode).
– Reference checksum incorrectly entered into the Motor Module
(p9899 not equal to r9898).
2003:
Acceptance test is required as a safety parameter has been
changed.
9999:
Subsequent response of another safety-related fault that occurred
when booting that requires an acceptance test.
© Siemens AG, 2006. All rights reserved