Siemens SINUMERIK 840D sl Function Manual page 356

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning
9.5 Acceptance test
FUNCTION TEST PART 2
Detailed function test incl. checking the values of the individually used SI functions
13.Test the SI function "safe operating stop" – SBH
(in each case with evaluated measurement diagram and measured values)
14.Test the SI function "safely-reduced speed" – SG
(in each case with evaluated measurement diagram and measured values)
15.Test the SI function "safety-related output n < n
(in each case with evaluated measurement diagram and measured values)
16.Test the SI function "safe software limits" – SE
(in each case with evaluated measurement diagram and measured values)
17.Test the SI function "safe cams" – SN
(check using the diagnostics display or assigned SGAs or with the evaluated
measuring diagrams and measured values)
18.If necessary, test the SI function "external stops"
(in each case with evaluated measurement diagram and measured values)
19.Test the SI function "SBC/SBT"
(in each case with evaluated measurement diagram and measured values)
COMPLETION OF THE REPORT
A report of the commissioning status that was checked is generated with the ap-
propriate counter-signatures
20.Check the SI machine data
21.Log the checksums (axis MD / SPL)
22.Completing the NCK commissioning (protect synchronous actions)
23.Completing the commissioning of the PLC
24.Verify the data backup
25.Have the report countersigned
APPENDIX
Reports/measurement records for FUNCTION TEST PART 1/2
Alarm logs/servo trace measurements
9-356
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
"