Siemens SINUMERIK 840D sl Function Manual page 303

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
p9752
SI message cases, counter
Number of safety message cases that have occurred since the last reset. The
safety message buffer is cleared by resetting the parameter to 0.
See also r9745, r9748, r9749, r9754, r9755, r9756
The parameter is automatically reset to 0 at power on.
Units:
Default value:
0
r9753[0...63]
SI message value for float values
Displays additional information about the safety message that has occurred for
float values.
See also r9744, r9747, r9748, p9752, r9754, r9755, r9756, p9759
Units:
Default value:
r9754[0...63]
SI message time received in days
Displays the relative system runtime in days when the safety message oc-
curred.
See also r9744, r9747, r9748, r7949, p9752, r9753, r9755, r9756, p9759
Units:
Default value:
days
r9755[0...63]
SI message time removed in milliseconds
Displays the relative system runtime in milliseconds when the safety message
was removed.
See also r9744, r9747, r9748, r7949, p9752, r9753, r9754, r9756, p9759
Units:
Default value:
ms
r9756[0...63]
SI message time removed in days
Displays the relative system runtime in days when the safety message was
removed.
See also r9744, r9747, r9748, r7949, p9752, r9753,r9754, r9755, p9759
Units:
Default value:
days
p9759
SI messages, acknowledge drive object
Acknowledges all safety messages present for a drive object.
Parameter should be set from 0 to 1 to acknowledge. After acknowledgement,
the parameter is automatically reset to 0.
See also r9744, r9747, r9748, r7949, p9752, r9753,r9754, r9755, p9759
Units:
Default value:
0
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
Minimum value:
Maximum value:
0
65535
Minimum value:
Maximum value:
Minimum value:
Maximum value:
Minimum value:
Maximum value:
Minimum value:
Maximum value:
Minimum value:
Maximum value:
0
1
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Data type:
U16
Checksum:
Data type:
REAL32
Checksum:
Data type:
U16
Checksum:
Data type:
U32
Checksum:
Data type:
U16
Checksum:
Data type:
U8
Protection level:
3
Effective:
Power ON
Protection level:
3
Effective:
Protection level:
3
Effective:
Protection level:
3
Effective:
Protection level:
3
Effective:
Protection level:
3
Effective:
8-303