Diagnostics
03.06
10.2 NCK safety alarms for Sinumerik 840D sl
The STOP of the active request is specified as detailed fault code for
the NCK and drive.
The following values are possible:
0 = No Stop
2 = Stop E
3 = Stop D
4 = Stop C
7 = Stop A
– 59
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[0] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 60
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[1] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 61
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[2] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 62
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[3] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 63
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[4] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 64
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[5] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 65
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[6] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
– 66
The setting in MD 36932 $MA_SAFE_VELO_OVR_FACTOR[7] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
© Siemens AG, 2006. All rights reserved
10-398