(2) Baud rate generator
The baud rate generator is the circuit which generates transmission and receiving
clocks which determine the transfer rate of the serial channels.
The input clock to the baud rate generator, φT0, φT2, φT8 or φT32, is generated by
the 6-bit prescaler which is shared by the timers. One of these input clocks is selected
using the BR0CR<BR0CK1:0> field in the baud rate generator control register.
The baud rate generator includes a frequency divider, which divides the frequency
by 1 or N + (16 − K)/16 to 16 values, determining the transfer rate.
The transfer rate is determined by the settings of BR0CR<BR0ADDE, BR0S3:0>
and BR0ADD<BR0K3:0>.
In UART mode
(1) When BR0CR<BR0ADDE> = 0
The settings BR0ADD<BR0K3:0> are ignored. The baud rate generator divides
the selected prescaler clock by N, which is set in BR0CK<BR0S3:0>. (N = 1, 2,
3 ... 16)
(2) When BR0CR<BR0ADDE> = 1
The N + (16 − K)/16 division function is enabled. The baud rate generator
divides the selected prescaler clock by N + (16 – K)/16 using the value of N set in
BR0CR<BR0S3:0> (N = 2, 3 ... 15) and the value of K set in BR0ADD<BR0K3:0>
(K = 1, 2, 3 ... 15)
Note: If N = 1 or N = 16, the N + (16 − K)/16 division function is disabled. Set
BR0CR<BR0ADDE> to 0.
In I/O interface mode
The N + (16 − K)/16 division function is not available in I/O interface mode. Set
BR0CR<BR0ADDE> to 0 before dividing by N.
The method for calculating the transfer rate when the baud rate generator is used
is explained below.
In UART mode
Baud rate =
In I/O interface mode
Baud rate =
Input clock of baud rate generator
Frequency divider for baud rate generator
Input clock of baud rate generator
Frequency divider for baud rate generator
91C824-126
TMP91C824
÷ 16
÷ 2
2008-02-20