Toshiba Q9+ Installation & Operation Manual page 221

Adjustable speed drives
Table of Contents

Advertisement

Integral Output Power Retention
Program Utilities Display Parameters
This parameter is used to set the disposition of the kWh meter
reading at power off.
Settings:
0 — Disabled
1 — Enabled
Integral Output Power Display Unit
Program Utilities Display Parameters
This parameter sets the unit of measure for the power/time
display.
Settings:
0 — 1=1 kWh
1 — 1=10 kWh
2 — 1=100 kWh
3 — 1=1000 kWh
4 — 1=10000 kWh
MAC Address 1
Program Communications Ethernet Settings
This parameter is used to configure the MAC Address 1
section of the MAC address of the device.
MAC
MAC
MAC
Address 1
Address 2
Address 3
https://www.toshiba.com/tic/
F748
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
MAC
MAC
Address 4
Address 5
F785
Direct Access Number —
Parameter Type — Selection List
Factory Default — Enabled
Changeable During Run — Yes
Direct Access Number —
Parameter Type — Selection List
Factory Default — (ASD-Dependent)
Changeable During Run — Yes
Direct Access Number —
Parameter Type — Numerical
Factory Default — 00
Changeable During Run — Yes
Minimum — 00
MAC
Maximum — 255
Address 6
F748
F749
F784
209