Table 12. Output Terminal Assignments, My Function Input Setting Assignments, and Parameter/Input Setting
Numbers for the FLA/B/C, O1A/O1B (OUT1), O2A/O2B (OUT2), OUT3 – OUT6, and R1 – R4.
Input
Param.
Setting
Setting
Lower-Limit Frequency
1000
0
Upper-Limit Frequency
1002
2
Low-Speed Signal
1004
4
Acceleration/Deceleration Completion
1006
6
Speed Reach Signal
1008
8
Failure FL (All Trips)
1010
10
Failure FL (Except EF, OCL, EPHO,
1012
12
and OL2)
Over-Current (OC) Alarm
1014
14
ASD Overload (OL1) Alarm
1016
16
Motor Overload (OL2) Alarm
1018
18
Over-Heat Alarm
1020
20
Over-Voltage Alarm
1022
22
Main Circuit (MOFF) Under-Voltage
1024
24
Alarm
Low-Current Alarm
1026
26
Over-Torque Alarm
1028
28
DBR Overload Alarm (not used)
1030
30
Emergency Off Active
1032
32
Retry Active
1034
34
PID Deviation Limit
1038
38
Run/Stop
1040
40
Serious Failure (OCA, OCL, EF, Phase
1042
42
Failure)
Light Failure (OL, OC1, 2, 3, or OP)
1044
44
Commercial Power/ASD Switching Out-
1046
46
put 1
Commercial Power/ASD Switching Out-
1048
48
put 2
Cooling Fan On/Off
1050
50
Jogging Operation Active (Jog Run
1052
52
Active)
EOI Keypad/Terminal Board Operation
1054
54
Switching
Cumulative Run-Time Alarm
1056
56
ProfiBus/DeviceNet/CC-Link Communi-
1058
58
cation Error
Forward/Reverse Switching
1060
60
Ready for Operation 1
1062
62
Ready for Operation 2
1064
64
1066
66
POFF Alarm
1070
70
Alarm Status Active
https://www.toshiba.com/tic/
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
Discrete Output Terminal Assignment Selections
Function
Input
Param.
Setting
Setting
Specified Data Output 3
1096
96
Specified Data Output 4
1098
98
Specified Data Output 5
1100
100
Specified Data Output 6
1102
102
Specified Data Output 7
1104
104
Light Load Detected
1106
106
Heavy Load Detected
1108
108
Positive Torque Limit
1110
110
Negative Torque Limit
1112
112
External Rush Suppression Relay Acti-
1114
114
vated
Completion of Stop Positioning
1118
118
L-STOP
1120
120
Power Failure Synchronized Operation
1122
122
Traverse in Progress
1124
124
Traverse Deceleration Active
1126
126
Part Replacement Alarm
1128
128
Over-Torque Alarm
1130
130
Frequency Command ½ Selection
1132
132
Failure FL (Except Emergency Off)
1134
134
External Device 1
1136
136
External Device 2
1138
138
External Device 3
1140
140
External Device 4
1142
142
External Device 5
1144
144
External Device 6
1146
146
Sealing Water
1148
148
NPSH/No Flow Alarm
1150
150
TBA Active
1154
154
TBA Alarm Float
1156
156
Local/Remote Switching
1158
158
Forced Operation (RUN)
1160
160
Forced Operation (Fire Speed)
1162
162
Under-Torque Detection
1164
164
Frequency Command From (RR/S4)
1166
166
Function
257