8.3 Suppressing Startup Upon Detection of a Serious Failure
To protect the equipment hardware, this equipment suppresses startup of the equipment when one of the following
incidents is detected during Windows
1. Fan failure
2. Remote shutdown signal input
NOTE
In the case of a remote shutdown signal input, startup is suppressed only when Enable automatic shutdown at
remote shutdown input is selected in the RAS Setup window. If the automatic shutdown setting is not selected,
startup is not suppressed. For details about how to use the RAS Setup window, see the HF-W2000 Model 58/55/50
RAS FEATURES MANUAL.
When a remote shutdown signal input is detected, the equipment displays a blue screen and then stops. For
information about the LED codes in this case, see 9.3 Bug Check Causes.
®