10.6.3 Status display feature

The status display feature displays the current RAID1 status. The RAID1 status is shown in the menu window of the
software RAID utility startup process.
This feature displays the information shown in the following table.
Item
Array Status
OPTIMAL
OPTIMAL
(MEDIA ERROR)
DEGRADE
DEGRADE
(MEDIA ERROR)
UNKNOWN
Drive1 Status
ONLINE
Drive2 Status
OFFLINE
NOT CONNECTED
NEW
REBUILD
INCOMPLETE DATA
ERROR

Table 10-2 Array status and drive status

Value
The array has redundancy and both drives are working in the
ONLINE state.
A media error is present in the OPTIMAL state.
The array does not have redundancy and is in degraded
operation. One of the drives is working in the ONLINE state.
A media error is present in the DEGRADE state.
The array status is unknown. The drive status is unknown, or no
array has been created.
Drives are working normally.
Disconnection occurred (due to an HDD failure).
No drive is installed in the drive bay.
A new drive that has not been used with the B model is
installed.
Rebuilding is in progress.
A disconnection occurred as a result of a data mismatch due to a
power failure or reset.
A drive failed during access.
Meaning
10-29